Award
Mobile Radiation Shielding
- Awarded to
- Not stated
- Agency
- 248-NETWORK Contract Office 8 (36C248)
- Estimated value
- $250,799
Statement of Need Radiation Shielding Systems GENERAL: James A. Haley Veterans Hospital (JAHVH) located at 13000 Bruce B. Downs Blvd, Tampa, FL 33612, has a requirement for RAMPART GUARDIAN ROVER and RAMPART IC SENTRY (BRAND NAME) to house and provide mobile radiation protection without the need for cumbersome lead vests during Cardiac Catheterization procedures in Cardiology Section of Medicine and Specialty Care. BACKGROUND: JAHVH currently provides patient care for veteran patients in the Cardiac Catheterization Labs of Cardiology Department Medicine and Specialty Care Service. In these Cardiac Catheterization Labs, the clinicians performing the procedure wear the typical bulky lead vests. PURPOSE: The requested radiation shielding systems would remove the need for clinicians to wear the bulky lead vests, providing more mobility which will lead to better quality care and efficient procedures. SCOPE: Vendor shall provide RAMPART GUARDIAN ROVER and RAMPART IC SENTRY radiation shields (BRAND NAME) that meets the physical, functional and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the needs of the government. CHARACTERISTICS: Rampart GUARDIAN ROVER Acrylic panels with 1.0mm of lead-equivalent protection Three panel system on smooth rolling, lockable casters that can be manipulated in position and orientation weighing under 330lbs Rechargeable battery-operated system for positioning adjustments Pliable radiation curtains that extend the coverage area, can be stored when not needed and are fully sterile IPX6 Protection Class for Washable Rampart SENTRY 0.5mm lead-equivalent protection that is height adjustable up to 72 and up to 26 wide Pliable soft shielding material Lockable caster wheels for smooth placement maneuvering and stationary placement when needed Low profile base and wheel system for tip-over/tripping protection Ergonomic handle for one-handed maneuvering Maximum weight of 115lbs for ease of movement SOFTWARE: There are no software requirements or compatibility needs regarding this request. INSTALLATION: Vendor will provide delivery and assembly/installation of the shielding systems in the Cardiac Catheterization Lab located within James A. Haley VA Hospital at 13000 Bruce B. Downs Blvd., Tampa FL 33612. TRAINING: Government will not require additional training. WARRANTY OF EQUIPMENT: Vendor shall provide standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment.
Key dates
- Posted
- August 17, 2026
- Award date
- August 17, 2026
Who is this buyer
Organization
Buying history
- Records324 total
- Opportunities / awards8 / 151
- Value range$0 – $24,119,935
- ActiveMay 26, 2026 – October 26, 2026
What they buy
- Clinical (253)
- Administrative (70)
- Insurance (1)
Set-asides used
- SDVOSB Set-Aside (FAR 19.14) (37)
- No Set aside used (24)
- Small Business Set Aside - Total (23)
Who holds their work today
- VALOR HEALTHCARE INC3 wins · $70,455,003 · last September 28, 2026
- BLUE CORD DESIGN AND CONSTRUCTION, LLC3 wins · $38,922,948 · last October 9, 2026
- LIFEFLEET SOUTHEAST INC2 wins · $33,915,994 · last October 1, 2026
- QUEST DIAGNOSTICS INCORPORATED14 wins · $25,015,809 · last October 1, 2026
- STANDARD COMMUNICATIONS INC2 wins · $16,900,000 · last October 9, 2026
Also open from this buyer
- 3D Image Reconstruction and Case Planning ServicesDue November 9, 2026 · Clinical
- Sources Sought | Ultrasound Guidance for Urology | OrlandoDue October 30, 2026 · Clinical
- FY27: Perfusionist Services| NFSGDue November 6, 2026 · Clinical
- Critical Care Hospital Bed Rental Services (Hill-Rom OR EQUAL)Due October 28, 2026 · Administrative
View source document →
Source link on sam.gov.
Source record
- Buyer type
- Federal
- Jurisdiction
- Federal (US)
- Category
- Clinical
- Set-aside
- Not stated
- NAICS
- 339112
- PSC
- 6515