HRC Ledger
Opportunity

Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system

Response due

September 9, 2026

Agency
National Institutes of Health Olao
Estimated value
Not stated
Notice of Intent: Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system. (75N98026Q01138) The National Institutes of Health (NIH) intends to award a Firm-Fixed-Price Purchase Order to Bridge12 Technologies under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. The National Institutes of Health (NIH), [Institute/Center], intends to solicit and negotiate on a sole-source basis with Bridge12 Technologies, Inc. for the acquisition of an automated high-velocity microsecond freeze hyper-quenching system for use with Q-band electron paramagnetic resonance (EPR) research applications. The Government requires a rapid mix/freeze-quench system capable of achieving a dead time of less than or equal to 500 microseconds (≤ 0.5 milliseconds) and compatible with Q-band EPR applications. This rapid dead-time capability is a critical minimum technical requirement because the system will be used to capture and preserve short-lived chemical intermediates and transient reaction states that would not be adequately resolved using conventional millisecond-scale freeze-quench technology. Market Research Market research was conducted through review of commercial vendor catalogs, published product specifications, technical literature, and consultation with subject matter experts within the EPR instrumentation community. The market research identified Bio-Logic as another commercial manufacturer offering freeze-quench instrumentation. However, published Bio-Logic specifications indicate a minimum dead time of approximately 9 milliseconds. This performance is substantially slower than the Government's required maximum dead time of 500 microseconds (0.5 milliseconds) and therefore does not satisfy the Government's minimum technical requirement. No additional commercial sources were identified through the Government's market research that offer a microsecond rapid mix/freeze-quench system compatible with Q-band EPR applications and capable of achieving the required ≤500-microsecond dead time. This notice is not a request for competitive quotations. However, any responsible source, including small business concerns (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, Veteran-Owned Small Business, Women-Owned Small Business, and Small Disadvantaged Business), that believes it can satisfy the Government's requirement may submit a capability statement demonstrating its ability to provide a product that meets the Government's minimum technical requirements. Capability statements must include sufficient documentation to establish the ability to furnish an equivalent system. A determination by the Government not to compete this proposed acquisition based upon responses to this notice is solely within the discretion of the Government. Responses must be submitted via email to vensonm@mail.nih.gov no later than 9:00 a.m. EDT on September 09, 2026. It is anticipated that an award will be issued approximately five (5) days after the closing date of this notice, provided no acceptable capability statements are received.

Key dates

Posted
September 2, 2026
Response due
September 9, 2026

Organization

NATIONAL INSTITUTES OF HEALTH OLAO

Buying history

  • Records263 total
  • Opportunities / awards10 / 20
  • Value range$0 – $30,482,226
  • ActiveJuly 15, 2026 – October 26, 2026

What they buy

  • Clinical (251)
  • Administrative (12)

Set-asides used

  • No Set aside used (68)
  • Small Business Set Aside - Total (14)

Who holds their work today

  1. EAGLE HEALTH, LLC1 win · $30,482,226 · last February 1, 2020
  2. LC INDUSTRIES INC1 win · $286,880 · last February 13, 2026

Also open from this buyer

View source document →

Source link on sam.gov.

Source record

Buyer type
Federal
Jurisdiction
Federal (US)
Category
Clinical
Set-aside
No Set aside used
NAICS
334516
PSC
6640