Opportunity
Alamar ARGO HT System
Response due
September 17, 2026
- Agency
- National Institutes of Health Olao
- Estimated value
- Not stated
ARGO HT instrument must be able to provide the following features: Must provide a fully automated, high-throughput proteomics platform capable of processing up to 288 samples per run Must provide an integrated qPCR system enabling end-to-end workflow from sample preparation to data output or pooled NGS library generation Must provide a total hands-on time of less than 30 minutes with simplified workflow and <5-minute instrument setup Must provide results in <6 hours for singleplex assays and <15 hours for multiplex NGS assays Must provide cartridge-based reagent system capable of supporting up to three consecutive runs without replacement Must provide liquid handling system for automated sample preparation for both qPCR and NGS workflows Must provide integrated onboard computing with intuitive user interface for streamlined operation and workflow management Must provide a built-in cloud-based primary analysis software (ARGO Command Center) and secondary analysis software (NULISA Analysis Software, NAS) Must provide capability to transform raw data into biological insights and publication-ready results through integrated data analysis tools Must provide compatibility with ultra-high sensitivity NULISA™ assay technology enabling attomolar-level detection of protein biomarkers Must provide scalable multiplexing capability supporting singleplex to high-plex (100s–1000s of targets) biomarker analysis Must provide broad sample compatibility including plasma, serum, cerebrospinal fluid (CSF), urine, and cell culture media Must provide an application programming interface (API) available for custom method development and instrument control Must provide compliance with major regulatory and safety standards including EMC, UL, CE, WEEE, ISO 13485, and ISO 9001 Must provide operating conditions supporting 15–24°C temperature range and 40–80% non-condensing humidity Must provide electrical compatibility with 100–240 V power supply, 50–60 Hz, and maximum power consumption of 1500 watts Must provide instrument footprint no larger than 1143 mm (W) × 661 mm (D) × 1016 mm (H) and weight no heavier than 250 kg Delivery must be within 90 days from award
Key dates
- Posted
- September 8, 2026
- Response due
- September 17, 2026
Who is this buyer
Organization
Buying history
- Records263 total
- Opportunities / awards10 / 20
- Value range$0 – $30,482,226
- ActiveJuly 15, 2026 – October 26, 2026
What they buy
- Clinical (251)
- Administrative (12)
Set-asides used
- No Set aside used (68)
- Small Business Set Aside - Total (14)
Who holds their work today
- EAGLE HEALTH, LLC1 win · $30,482,226 · last February 1, 2020
- LC INDUSTRIES INC1 win · $286,880 · last February 13, 2026
Also open from this buyer
- Clinical Research Support and Collaboration for NHGRI ProtocolsDue November 13, 2026 · Clinical
- NOI - 4D-Nucleofector Core Unit and X UnitDue November 5, 2026 · Clinical
- Reagents and consumables for Roche immunostainersDue October 28, 2026 · Clinical
- Combines Synopsis Solicitation- Automated SpatialDue November 5, 2026 · Clinical
View source document →
Source link on sam.gov.
Source record
- Buyer type
- Federal
- Jurisdiction
- Federal (US)
- Category
- Clinical
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 334516
- PSC
- 6640